Contact Getein
Products
Cardiopulmonary Diagnosis and Rehabilitation Solution
Cardiopulmonary Diagnosis and Rehabilitation Solution

One-stop Diagnosis + Cardiopulmonary Rehabilitation Solution

Cardiopulmonary Rehabilitation can improve cardiac and systemic dysfunction caused by cardiovascular diseases, solve residual disease problems after acute and severe diseases, prevent recurrence of cardiovascular events, and help patients return to a healthy life.

 

One-stop Diagnosis + Cardiopulmonary Rehabilitation Solution

 

Empowered by Technology, Enjoy Healthy Life

 


 

 

Diagnosis + Cardiopulmonary Rehabilitation Process —— Laboratory Examination

 

 

 

Test Items:

Cardiopulmonary Biomarkers —— Biomarkers for Heart Failure: NT-proBNP, BNP

                                                           Biomarkers for AMI: cTnI, CK-MB, Myo

                                                           Thrombosis Biomarker: D-Dimer

 

Applicable Devices

 

 

 

Diagnosis + Cardiopulmonary Rehabilitation Process —— Cardiopulmonary Evaluation

 

Cardiopulmonary Exercise Testing System

Smax58ce-sp

 

 

Product Features

 

 

Product Usage

 

  • Distinguish between left and right heart failure, and differentiate between heart and lung dyspnea
  • Objective and quantitative grading of severity of cardiopulmonary function limitation
  • Surgical risk assessment
  • Develop exercise prescriptions for cardiac rehabilitation and respiratory rehabilitation
  • Evaluate patients' activities of daily living

  • Healthcare management of high-risk people, eg. people who suffer from hypertension

 

 

 

Product Usage

  • Evaluate whether the patient can receive a cardiopulmonary exercise test (pre-evaluation)
  • Test patients' safe exercise intensity
  • Determine exertional dyspnea and provide medication instruction

  • Bedside exercise for cardiac rehabilitation

 

 

 

Diagnosis + Cardiopulmonary Rehabilitation Process —— Exercise Training

 

 

 

Exercise and Rehabilitation Monitoring System

 

Product Usage

 

  • Monitor all connected ergometers and achieve collective exercise through the V3.0 rehabilitation management system

 

 

 

 

One-stop Diagnosis + Cardiopulmonary Rehabilitation Solution —— Clinical Application

 

 

 

 

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.
  • Cardiopulmonary Diagnosis and Rehabilitation Solution
Submit
Related Products
ASO Rheumatism Fast Test Kit ASO Rheumatism Fast Test Kit
ASO Fast Test Kit (Immunofluorescence Assay)
>ASO Fast Test Kit  (Immunofluorescence Assay)   Intended Use ASO Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of anti streptolysin "O" antibody (ASO) in serum, plasma or whole blood samples. ASO is a very valuable marker for the diagnosis of group A streptococcal infection, its titer can reflect the severity of infection. Some diseases will lead to a significant increase in ASO titer, such as wind damp heat, acute glomerulonephritis, nodular erythema, scarlet fever, acute tonsillitis.   About ASO Streptolysin "O", a protein with hemolytic activity, is one of the important metabolites of group A streptococcus. It can dissolve the red blood cells of human and some animals. Streptolysin "O" has strong antigenicity. When human is infected with group A hemolytic streptococcus, B lymphocytes will secrete corresponding antibodies under the stimulation of streptolysin "O", that is, anti streptolysin "O" (ASO). This antibody can neutralize streptolysin "O" and disable its hemolytic ability. ASO began to rise one week after group A Streptococcus infection, peaked in 4-5 weeks and lasted for several months.As the infection subsides, ASO decreased and returned to normal value within 6 months. The disease condition can be judged by repeated measurements over time. The increase of ASO over time indicates the early stage of infection, decrease indicates the subside stage of infection. The lack of decline in ASO titer suggested the possibility of recurrent or chronic infection.   Specification   Test Item Sample Type Method Storage Condition ASO S/P/WB Immunofluorescence Assay 4-30℃ Detection Range Test Time Cut-off Value Shelf Life 60.0-1370.0 IU/mL 10 min 400.0 IU/mL 24 months   Applicable Device   Getein 1100 Immunofluorescence Quantitative Analyzer Getein 1160 Immunofluorescence Quantitative Analyzer Getein 1180 Immunofluorescence Quantitative Analyzer Getein 1200 Immunofluorescence Quantitative Analyzer Getein 1600 Immunofluorescence Quantitative Analyzer    
Leading T4 Fast Test Kit (Immunofluorescence Assay) Manufacturer Leading T4 Fast Test Kit (Immunofluorescence Assay) Manufacturer
T4 Fast Test Kit (Immunofluorescence Assay)
>Getein T4 Fast Test Kit is used in the monitoring of hyperthyroidism and hypothyroidism, and also used as an aid in the functional diagnosis of thyroidea.    
Metis 800 Modular System supplier Metis 800 Modular System supplier
Metis 800 Modular System
>Metis 800 Modular System (Magicl 6000+Getein 3200+BHA-5100)  
Leading Anti-CCP Fast Test Kit (lmmunofluorescence Assay) Manufacturer Leading Anti-CCP Fast Test Kit (lmmunofluorescence Assay) Manufacturer
Anti-CCP Fast Test Kit (lmmunofluorescence Assay)
>Getein Anti-CCP Fast Test Kit is intended for in vitro quantitative determination of anti-CCP in serum, plasma or whole blood samples. The test is designed to aid in the diagnosis of autoimmune diseases, such as rheumatoid arthritis (RA).
TnT Quantitative POC Fast Test Kit TnT Quantitative POC Fast Test Kit
TnT Fast Test Kit (Immunofluorescence Assay)
>Getein TnT Fast Test Kit is used as an aid for the early screening of acute myocardial infarction (AMI), heart failure, unstable angina pectoris, myocarditis and other myocardial injuries, it can also be used for the assessment of prognosis and risk stratification of acute pulmonary embolism and the monitoring of myocardial injury in thoracic surgery.
Leading HBsAg Fast Test Kit (Immunofluorescence Assay) Manufacturer Leading HBsAg Fast Test Kit (Immunofluorescence Assay) Manufacturer
HBsAg Fast Test Kit (Immunofluorescence Assay)
>Getein HBsAg Fast Test Kit is suitable for blood supply screening and clinical diagnosis of hepatitis B virus infection.
Automatic Clinical Chemistry Analyzer Automatic Clinical Chemistry Analyzer
BBA-300 Automatic Clinical Chemistry Analyzer
>BBA-300 Automatic Clinical Chemistry Analyzer     “No-Wait” Emergency Test Mode  No need of pausing the testing procedure, emergency samples are given test priority and can be tested at any time during analysis. Stable & reliable clinical chemistry test   Highly-Efficient and Convenient Test  Constant test speed of 300 T/h Emergency samples in test priority at any time LIS bi-directional connectivity Automatic test report printing    Multifunctional and Precise Sample Probe  Highly-polished probe Automatic inside and outside probe washing, reducing cross contamination Highly sensitive liquid level detection sensor Actively monitoring reagent volume Protection of probe collision Auto adjustment of sampling depth of sample probe    Sample and Reagent Unit  45 sample positions 90 reagent positions Built-in refrigeration system, continual 24-hour on-board cooling Built-in barcode reader for reagents and samples (optional item)    Reaction Unit  120 cuvettes, can be replaced separately The cuvettes are made of new-type non-crystalline optical plastic with better light transmittance Minimum reaction volume: 150 μL Stable and precise temperature control (37.0 ± 0.2°C) 5-step cuvette Wash Station, thorough cleaning    Stirring Unit  Independent stirring paddle lmported Teflon coating technology Effectively preventing cross contamination    Advanced Operation System  lntuitive user-friendly interface, easy to learn and use Auto sample dilution Auto stopping and warning when reagents or samples run out Calibration with linear or non-linear curves. Multi-point calibration Automatically detecting cuvettes status and screening flawed cuvettes   Technical Parameters   Test Principles Turbidimetry, colorimetry Test Methods End-point method, Rate method, two-point method Test Speed Constant speed of 300 T/h Sample Types Blood, urine, hydrothorax, cerebrospinal fluid Reaction Temperature 37.0 ± 0.2°C (constant temperature) Dimensions Floor-standing: 1060 mm × 660 mm × 1230 mm Benchtop: 1060 mm × 660 mm × 540 mm Weight Floor-standing: 140 kg Benchtop: 85 kg     Floor-standing Benchtop   Test Item     Liver Function TBA, AFU, ALT, AST, ALP, AMM, GGT, TP, GPDA, GLDH, ALB, TB, DB, PA, CHE, ADA, 5’-NT, LAP, MAO, CG, GR Renal Function CRE-E, Urea, UA, β2-MG, CYS-C, MALB, NAG, RBP, CSF Specific Protein and Rheumatism ASO, RF, CRP,  Fer, CCP, Hs-CRP, TRF, RBP, C3, C4, IgA, IgM, IgG Glycometabolism GLU-HK, GLU-OX, FMN, D3-H, HbA1c, GA, LAC, NEFA Blood Lipids and Cardiovascular TG, TCH, HDL-C, LDL-C, ApoA1, ApoB, ApoE, Lp(a), HCY, NEFA, ACE, Myo, Lp-PLA2 Pancreatitis LPS, AMY Venous Thromboembolism and Coagulation D-Dimer Trace Elements and Electrolytes Ca, Mg, P, CO2, Fe, Na, Cl, K, UIBC Myocardial Enzyme CK, CK-MB, CK-MB mass, LDH, HBDH, LDH1 Tumor SA, AFU, Fer, TRF Gastric Function PG Ⅰ, PG Ⅱ      
Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service