Getein CK-MB/cTnI/H-FABP Fast Test Kit is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).

  • Test Item:

    CK-MB/cTnI/H-FABP
  • Sample Type:

    Plasma/Serum/Whole Blood
  • Test Time:

    10 min
  • Methodology:

    Immunofluorescence Assay

CK-MB/cTnI/H-FABP Fast Test Kit

(Immunofluorescence Assay)

 


 

Intended Use

CK-MB/cTnI/H-FABP Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of CK-MB/cTnI/H-FABP in human serum, plasma or whole blood samples. This test is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).

 

About CK-MB/cTnI/H-FABP

CK-MB: Creatine kinases are dimer isozymes composed of two monomer subunits, CK-M (for skeletal muscle derived) and CK-B (for brain derived), which can form all three combinations of monomers: CK-BB, CK-MM, and CK-MB. BB is found primarily in the brain. Skeletal muscles primarily contain the MM isoform, with trace amount of MB (around 1-4% of total CK activity). Cardiac muscles also contain the MM isoform, but higher amount of MB, typically around 20% of total CK activity. CK-MB is a more sensitive marker of myocardial injury than total CK activity, because it has a lower basal level and a much narrower normal range.

cTnI: Troponin complex consists of three regulatory proteins: T, which connects the troponin complex and tropomyosin (another cardiac muscle regulatory protein); I, which prevents muscle contraction in the absence of calcium; and C, which binds calcium. Cardiac troponin I (MW 22.5 kDa) and the two skeletal muscle isoforms of troponin I have considerable amino acid sequence homology, but cTnI contains an additional N-terminal sequence and is highly specific for myocardia. Clinical studies have demonstrated the release of cTnI into the blood stream within hours following acute myocardial infarctions (AMI) or ischemic damage.

H-FABP: H-FABP (Heart-type Fatty Acid Binding Protein) that finds in abundance in cardiomyocytes is one of the Fatty acid-binding proteins (FABPs). The molecular weight of H-FABP is about 15 kDa, the combination of their low molecular weight and cytoplasmic location means that H-FABP proteins are released very rapidly following Acute Myocardial Infarction (AMI). H-FABP has been repeatedly shown to a highly sensitive early rise biomarker across the full spectrum of ACS, detectable as early as 30 minutes following the onset of an ischemic episode.

 

Specifications

 

Test Item

Sample

Detection Range

Storage Condition

CK-MB/cTnI/H-FABP

P/S/WB

CK-MB:2.50ng/ml~80.00ng/ml

cTnI: 0.10 ng/ml~50.00 ng/ml,

H-FABP: 2.00 ng/ml~100.00 ng/ml

4-30℃

Method

Test Time

Cut-off Value

Shelf Life

Immunofluorescence

Assay

10 min

CK-MB: 5.0 ng/ml

cTnI: 0.1 ng/ml

H-FABP: 6.36 ng/ml

24 months

 

Applicable Device

Getein1100 Immunofluorescence Quantitative Analyzer

Getein1600 Immunofluorescence Quantitative Analyzer

 

Clinical Application

1.    As an aid in the diagnosis of various causes of chest pain;

2.    As an aid in the diagnosis of myocardial injury;

3.    As an aid in the early diagnosis and risk classification of ACS.

4.    As an aid in the monitoring and prognostic assessment of clinical treatment.

 

 

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.
  • CK-MB/cTnI/H-FABP Quantitative POC Test Kit
Submit
Related Products
CK-MB Quantitative POC Test Kit CK-MB Quantitative POC Test Kit
CK-MB Fast Test Kit (Immunofluorescence Assay)
>Getein CK-MB Fast Test Kit is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).    
cTnI Quantitative POC Test Kit cTnI Quantitative POC Test Kit
Cardiac Troponin I Fast Test Kit (Immunofluorescence Assay)
>Getein Cardiac Troponin I Fast Test Kit is used as an aid in the diagnosis of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).      
hs-cTnI Quantitative POC Fast Test Kit hs-cTnI Quantitative POC Fast Test Kit
hs-cTnI Fast Test Kit (Immunofluorescence Assay)
>Getein hs-cTnI Fast Test Kit can be used as an aid in the diagnosis of myocardial infarction (MI).
BNP Quantitative POC Fast Test Kit BNP Quantitative POC Fast Test Kit
BNP Fast Test Kit (Immunofluorescence Assay)
>Getein BNP Fast Test Kit is used as an aid in the diagnosis of congestive heart failure and for the risk stratification of patients with acute coronary syndromes (ACS).
CK-MB/cTnI Quantitative POC Test Kit CK-MB/cTnI Quantitative POC Test Kit
CK-MB/cTnI Fast Test Kit (Immunofluorescence Assay)
>Getein CK-MB/cTnI Fast Test Kit  is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).
CK-MB/cTnI/Myo Quantitative POC Test Kit CK-MB/cTnI/Myo Quantitative POC Test Kit
CK-MB/cTnI/Myo Fast Test Kit (Immunofluorescence Assay)
>Getein CK-MB/cTnI/Myo Fast Test Kit is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).
H-FABP Quantitative POC Fast Test Kit H-FABP Quantitative POC Fast Test Kit
H-FABP Fast Test Kit (Immunofluorescence Assay)
>Getein H-FABP Fast Test Kit is used in the early diagnosis of AMI and pulmonary embolism, and monitoring of chronic heart failure.
NT-proBNP Quantitative POC Fast Test Kit NT-proBNP Quantitative POC Fast Test Kit
NT-proBNP Fast Test Kit (Immunofluorescence Assay)
>Getein NT-proBNP Fast Test Kit is used as an aid in the clinical diagnosis, prognosis and evaluation of Heart Failure (HF).
Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service